Diagnosis / Faults and Alarms 11/03
SINAMICS G150
10-50 Operating Manual
F35832 TM DRIVE-CLiQ: Telegram failure
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: - Check for break in DRIVE-CLiQ or faulty contacts in connector.
- Check 24 V supply of affected component.
- Replace affected component.
See also: p9916
Acknowl.: Immediate
F35833 TM DRIVE-CLiQ: fault in cyclic data transfer
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: - Check firmware states of affected components.
- Replace affected component.
Acknowl.: Immediate
F35834 TM DRIVE-CLiQ: Hardware defect
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: Replace affected component.
Acknowl.: Immediate
F35835
F35836
TM DRIVE-CLiQ: fault in cyclic data transfer
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: - Check firmware states of affected components.
- Replace affected component.
Acknowl.: Immediate
F35837
F35838
TM DRIVE-CLiQ: Hardware defect
Reaction: OFF2
Cause: There is a DRIVE-CLiQ communication error between the control unit and the affected
terminal module.
Remedy: Replace affected component.
Acknowl.: Immediate
F35860 -
F35871
CU DRIVE-CLiQ: Data transfer faulted / Telegram faulted
Reaction: OFF2
Cause: DRIVE-CLiQ communication between control unit and at least one other component is
defective.
Fault value
(r0949):
Bit 0 - 7: Number of the affected component
Bit 8 - 31: Reserved
Remedy: - Check cabinet design and cabling for EMC conformity.
- Replace affected component.
Acknowl.: Immediate
F35872
F35873
CU DRIVE-CLiQ: fault in cyclic data transfer
Reaction: OFF2
Cause: Reserved for later use.
Remedy: Reserved for later use.
Acknowl.: Immediate