Technical Data 11/03
SINAMICS G150
12-10 Operating Manual
Table 12-11 Version C, 380 V – 480 V, part 3
Category Unit
Order no. 6SL3710- 1GE37-5CA0 1GE38-4CA0 1GE41-0CA0
Rated motor output kW 400 450 560
Rated connection voltage V 3 AC 380 V to 480 V ±10 % (-15 % < 1 min)
Rated input current A 785 883 1034
Rated output current A 745 840 985
Base load current A 725 820 960
Power loss kW 9.6 10.1 14.4
Cooling air requirement m³/s 0.78 0.78 1.48
Sound pressure level at 50/60
Hz
dB(A) 70/73 70/73 72/75
Power connection
Recommended: DIN VDE
AWG / MCM
Maximum: DIN VDE
AWG / MCM
Fastening screw
mm
2
mm
2
2 x 300
2 x (800)
8 x 240
8 x (600)
M12 (4 holes)
4 x 150
4 x (400)
8 x 240
8 x (600)
M12 (4 holes)
4 x 185
4 x (500)
8 x 240
8 x (600)
M12 (4 holes)
Motor connection
Recommended: DIN VDE
AWG / MCM
Maximum: DIN VDE
AWG / MCM
Fastening screw
mm
2
mm
2
2 x 300
2 x (800)
8 x 240
8 x (600)
M12 (4 holes)
4 x 150
4 x (400)
8 x 240
8 x (600)
M12 (4 holes)
4 x 185
4 x (500)
8 x 240
8 x (600)
M12 (4 holes)
Protective earth connection
Fastening screw
M12 (8 holes)
M12 (8 holes)
M12
(10 holes)
Approx. weight (standard
version)
kg 670 670 980
Dimensions (w x h x d) mm 600 x 2000 x 600 600 x 2000 x 600 1000 x 2000 x 600
Recommended protection
Cond./semi-cond. protection
Rated current
Size to DIN 43 620-1
A
3NE1 448-2
850
3
Circuit-breaker
Circuit-breaker

Table of Contents