11/03 Parameterlist
SINAMICS G150
Operating Manual Parameterlist-
1
Parameterlist
0002 - Drive status ................................................................................................................... 10-4
0020 - Speed setpoint smoothed ............................................................................................... 6-8
0021 - Actual speed smoothed................................................................................................... 6-8
0024 - Output frequency............................................................................................................. 6-8
0025 - converter output voltage smoothed................................................................................. 6-8
0026 - DC link voltage smoothed ............................................................................................... 6-8
0027 - Absolute actual current smoothed .................................................................................. 6-8
0028 - Control factor smoothed..................................................................................................6-8
0029 - Field-producing current component ................................................................................ 6-8
0030 - Torque-producing current component............................................................................. 6-8
0031 - Actual torque smoothed .................................................................................................. 6-8
0032 - Output smoothed............................................................................................................. 6-8
0035 - Motor temperature........................................................................................................... 6-8
0036 - Converter overload.......................................................................................................... 6-8
0037 - Converter temperature....................................................................................................6-8
0046 - Missing enable signals.................................................................................................. 10-4
0050 - Active command data set (CDS)................................................................................... 10-5
0060 - Speed setpoint upstream of setpoint filter....................................................................... 8-4
0061 - Motor speed unsmoothed ............................................................................................... 8-4
0062 - Speed setpoint downstream of filter................................................................................ 6-8
0063 - Actual speed after smoothing ..................................................................................6-8, 8-4
0064 - Control deviation ...................................................................................................... 6-8, 8-4
0065 - Slip frequency ..........................................................................................................6-8, 8-4
0066 - Output frequency...................................................................................................... 6-8, 8-4
0068 - Output current ................................................................................................................. 8-4
0069 - Actual phase current ....................................................................................................... 8-4
0070 - DC link voltage ................................................................................................................ 8-4
0072 - Output voltage................................................................................................................. 6-8
0074 - Control factor................................................................................................................... 6-8
0074 - Speed setpoint upstream of setpoint filter....................................................................... 8-4
0075 - Field-producing current setpoint ..................................................................................... 8-4
0076 - Field-producing actual current ........................................................................................ 8-4
0077 - Torque-producing current setpoint.................................................................................. 8-4
0078 - Torque-producing actual current..............................................................................6-8, 8-4
0079 - Torque setpoint ............................................................................................................... 8-4
0080 - Actual torque value ......................................................................................................... 6-8
0082 - Output power................................................................................................................... 8-4
0083 - Flux setpoint.................................................................................................................... 8-4
0084 - Actual flux........................................................................................................................ 8-4
0088 - DC link voltage setpoint .................................................................................................. 8-4
0089 - Phase voltage ................................................................................................................. 8-4
0721 - Actual terminal value CU320 digital inputs ................................................................... 10-5
0747 - Status of digital outputs CU320 .................................................................................... 10-5
1001 - Fixed speed setpoint 01................................................................................................ 6-26
1002 - Fixed speed setpoint 02................................................................................................ 6-26
1003 - Fixed speed setpoint 03................................................................................................ 6-26
1024 - Fixed speed setpoint active ...................................................................................6-8, 6-26
1037 - Motor potentiometer maximum speed .......................................................................... 6-24
1038 - Motor potentiometer minimum speed ........................................................................... 6-24
1047 - Motor potentiometer ramp-up time................................................................................ 6-24
1048 - Motor potentiometer ramp-down time ........................................................................... 6-24