4
03.04 Machine Operating Area
4.6 Automatic mode
4
Ó Siemens AG, 2004. All rights reserved
SINUMERIK 840D/840Di/810D Operator's Guide HMI Advanced (BAD) – 03.04 Edition 4-155
Case 2
· Search target 1: The NC jumps to line 8 of the search target.
· Search target 2: See above
· Search target 3: See above
On NC Start, the subroutine SUBPRG3.SPF is started and processed
starting at the destination line.
Operating sequence
"AUTO" mode is selected in the "Machine" operating area.
The channel is in the reset state.
The program in which the block search is to be performed is selected.
Block
search
Switch to the "Search position" dialog.
Define search destination in program editor:
Search
position
The current selected program level is displayed.
The block search via "Search position" is only possible for programs
which have been loaded onto the NC and not for programs executed
from the hard disk.
Position the cursor bar on a destination block of your choice in the
part program.
Program
level +
or
Program
level -
If an interruption point is available on the NC, you can switch back
and forth between the program levels.
Ext. without
calc.
Start search without calculation for external programs.
Defining the search destination in the search pointer:
Search
pointer
Once the softkey "search pointer" has been pressed, a screen form
with the program pointer is displayed.
It contains input fields for program name, search type (block
number, text, ...) and search destination (content). The cursor is
positioned in the input field for the "search type".
Type 1 (block number) and type 5 (line number) are possible as
search target types.
Ext. without
calc.
Start search without calculation for external programs.