3 Setting up functions 12/2008
3.4 Fault services
© Siemens AG 2008 All Rights Reserved
3-144 ePS Network Services, Function Manual (FH) - Release 12/2008
Description of the "Upload PLC data" function
The diagnostic action "Upload PLC data" permits some or all of the PLC data
blocks to be uploaded the ePS server on a trigger event, using a control monitor.
Notice
The PLC data blocks are available on the ePS server without a specific format.
Precisely one contiguous range of the same data block can be selected for
uploading for each control monitor.
For the purpose of displaying the DB content, the data from the ePS Network
Services menu (machine events) must be exported and saved. A hexadecimal
editor or byte-by-byte conversion in Excel is recommended for visualization
purposes.
In the case of data block content that changes dynamically from the point directly
after the trigger event up to the point when transfer to the ePS server is complete,
due to the limited bandwidth of the communication channel to the PLC, it cannot
be guaranteed that the statuses are from a single cycle.
Fig. 3-42: Adding PLC data blocks
Fig. 3-43: PLC data block (details)
Field Content Type
Add/open Switch to the menu for configuring the
data to be uploaded.
If a configuration is added, the entry
fields will not contain any
specifications. If an existing
configuration is being changed, the
configured entries will appear.
ACTION
Delete Deletes a PLC data block to be
uploaded from the list
ACTION
Data block No. Number of the data block to be loaded
to the ePS server
DISPLAY
INPUT
(Digits from 0 to
9999)