A.9 Information List
591
7UT613/63x Manual
C53000-G1176-C160-2
200.2421 Time Overcurrent 1Phase picked
up (O/C 1Ph PU)
1Phase O/C OUT * ON
OFF
* LED BO 76 171 2 Yes
200.2451 Time Overcurrent 1Phase TRIP
(O/C 1Ph TRIP)
1Phase O/C OUT * ON * LED BO 76 172 2 Yes
200.2492 O/C 1Phase err.:No auxiliary CT
assigned (O/C 1Ph Err CT)
1Phase O/C OUT ON * * LED BO
200.2502 >BLOCK Time Overcurrent 1Ph.
I>> (>BLK 1Ph. I>>)
1Phase O/C SP * * * LED BI BO
200.2503 >BLOCK Time Overcurrent 1Ph.
I> (>BLK 1Ph. I>)
1Phase O/C SP * * * LED BI BO
200.2514 Time Overcurrent 1Phase I>>
BLOCKED (O/C 1Ph I>> BLK)
1Phase O/C OUT ON
OFF
ON
OFF
* LED BO 76 167 1 Yes
200.2515 Time Overcurrent 1Phase I>
BLOCKED (O/C 1Ph I> BLK)
1Phase O/C OUT ON
OFF
ON
OFF
* LED BO 76 166 1 Yes
200.2521 Time Overcurrent 1Phase I>>
picked up (O/C 1Ph I>> PU)
1Phase O/C OUT * ON
OFF
* LED BO 76 177 2 Yes
200.2522 Time Overcurrent 1Phase I>
picked up (O/C 1Ph I> PU)
1Phase O/C OUT * ON
OFF
* LED BO 76 174 2 Yes
200.2551 Time Overcurrent 1Phase I>>
TRIP (O/C1Ph I>> TRIP)
1Phase O/C OUT * ON m LED BO 76 179 2 Yes
200.2552 Time Overcurrent 1Phase I>
TRIP (O/C 1Ph I> TRIP)
1Phase O/C OUT * ON m LED BO 76 175 2 Yes
200.2561 Time Overcurrent 1Phase: I at
pick up (O/C 1Ph I:)
1Phase O/C VI ON
OFF
76 180 4 No
204.2404 >BLOCK Thermal Overload Pro-
tection 2 (>BLK Therm.O/L2)
Therm.Overload2 SP * * * LED BI BO
204.2411 Thermal Overload Protection 2
OFF (Therm.O/L2 OFF)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2412 Thermal Overload Protection 2
BLOCKED (Therm.O/L2 BLK)
Therm.Overload2 OUT ON
OFF
ON
OFF
* LED BO
204.2413 Thermal Overload Protection 2
ACTIVE (Therm.O/L2 ACT)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2421 Thermal Overload 2 picked up
(O/L2 Th. pickup)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2451 Thermal Overload 2 TRIP
(Therm.O/L2 TRIP)
Therm.Overload2 OUT * ON
OFF
m LED BO
204.2491 Th. Overload 2 Not avail. for this
obj. (O/L2 Not avail.)
Therm.Overload2 OUT ON * * LED BO
204.2494 Th. Overload 2 err.:adverse
Adap.fact.CT (O/L2 Adap.fact.)
Therm.Overload2 OUT ON * * LED BO
204.2601 >Emergency start Th. Overload
Protec. 2 (>EmerStart O/L2)
Therm.Overload2 SP ON
OFF
**LEDBIBO
204.2602 Th. Overload 2 Current Alarm (I
alarm) (O/L2 I Alarm)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2603 Thermal Overload 2 Alarm (O/L2
Θ Alarm)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2604 Thermal Overload 2 hot spot Th.
Alarm (O/L2 ht.spot Al)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2605 Thermal Overload 2 hot spot Th.
TRIP (O/L2 h.sp. TRIP)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2606 Thermal Overload 2 aging rate
Alarm (O/L2 ag.rate Al)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2607 Thermal Overload 2 aging rate
TRIP (O/L2 ag.rt.TRIP)
Therm.Overload2 OUT ON
OFF
**LEDBO
204.2609 Th. Overload 2 No temperature
measured (O/L2 No Th.meas)
Therm.Overload2 OUT ON * * LED BO
No. Description Function
Type of Information
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log On/Off
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIPROTEC 7UT63 series and is the answer not in the manual?

Siemens SIPROTEC 7UT63 series Specifications

General IconGeneral
BrandSiemens
ModelSIPROTEC 7UT63 series
CategoryProtection Device
LanguageEnglish

Related product manuals