EasyManua.ls Logo

Siemens SITRANS F FM100 - Page 59

Siemens SITRANS F FM100
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SITRANS FM100
page 58 A5E48762204-AA
Index
[hex]
Name
Description
Factory default
Max Value
Min Value
Length
[Bytes]
Data Type
Access
Device Status Information
0x0024
DeviceStatus
0 - Device OK
1 - Maintenance
required
2 - Out of
specification
3 - Functional
check
4 - Failure
1
UIntegerT
R
0x0025
DetaildDevice
Status
max. 20
ArrayT of
OctetString
T3
R
Display Configuration
0x0100
DisplayOrientation
Orientation of
display
1
(0) - Landscape
(1) - Portrait Flip
(2) - Landscape Flip
(3) - Portrait
1
UIntegerT
R/W
0x0103
DisplayLayout
Single or dual
layout
1
(0) - single
(1) - dual
1
UIntegerT
R/W
0x0104
UpperDisplay
Source for the
upper display
0
(0) - Flow
(1) - Volume
(2) - Temperature
(3) - Part Volume
1
UIntegerT
R/W
0x0105
LowerDisplay
Source for the
lower display
2
(0) - Flow
(1) - Volume
(2) - Temperature
(3) - Part Volume
1
UIntegerT
R/W
0x0106
DisplayRefresh
Time
Refresh intervall
for the display [s]
0,5
10,0
0,5
4
FloatT
R/W
0x010A
LeftHotkey
Function
Function for left
hotkey
0
(0) - Off
(1) - Value
(2) - MinMax
1
UIntegerT
R/W
0x010B
RightHotkey
Function
Function for right
hotkey
0
(0) - Off
(1) - Value
(2) - MinMax
1
UIntegerT
R/W
0x010C
LeftHotkeySource
Source for the left
hotkey
0
(0) - Flow
(1) - Volume
(2) - Temperature
(3) - Part Volume
1
UIntegerT
R/W
0x010D
RightHotkeySource
Source for the
right hotkey
0
(0) - Flow
(1) - Volume
(2) - Temperature
(3) - Part Volume
1
UIntegerT
R/W
0x010E
SensitivityOptical
Keys
Sensitivity for the
optical keys
0
(0) - low
(1) - middle
(2) - high
1
UIntegerT
R/W
0x010F
AutomaticMenu
Leave
Automatic menu
leave if the
timeout [s] is hit.
0 = timeout not
active
0
60
0
1
UIntegerT
R/W
Output 1 (In IO-Link mode output 1 can be parameterized individual, operating mode can only be changed manually)