Param‐
eter ID
Meter
version
Display
view
Parameter/data type Factory settings Data range
Fixed parameter or meter data that are not changeable
614* All - Latest Log period status infor‐
mation*
Meter operation conditions in
log period
1: Totalizer 1 or 2 changed or
reset
2: Tariff setting changed or reset
3: Tariff register changed or re‐
set
4: Date - time changed
5: Alarm active in logged period
(See alarm fault log for same pe‐
riod)
6: Fault log has been reset
7: HW lock broken
8: Power Up
If none of the information has
been logged, the message is
"No Faults"
615* All L2 Date of log period 2
616* All L2 Log period 2 totalized (1)
617* All - Log period 2 totalized (2)
618* All - Log period 2 fault status See 613
619* All - Log period 2 status informa‐
tion
See 614
620* All L3 Date of log period 3
621* All L3 Log period 3 totalized (1)
622* All - Log period 3 totalized (2)
623* All - Log period 3 fault status See 613
624* All - Log period 3 status informa‐
tion
See 614
625* All L4 Date of log period 4
626* All L4 Log period 4 totalized (1)
627* All - Log period 4 totalized (2)
628* All - Log period 4 fault status See 613
629* All - Log period 4 status informa‐
tion
See 614
630* All L5 Date of log period 5
631* All L5 Log period 5 totalized (1)
632* All - Log period 5 totalized (2)
633* All - Log period 5 fault status See 613
634* All - Log period 5 status informa‐
tion
See 614
635* All L6 Date of log period 6
636* All L6 Log period 6 totalized (1)
637* All - Log period 6 totalized (2)
638* All - Log period 6 fault status See 613
Appendix
C.2 Parameter lists
SITRANS MAG 8000
148 Operating Instructions, 11/2018, A5E03071515-AE