d High flow rate warning (alarm limits are configurable)
A Reverse high flow rate warning (alarm limits are configurable)
*) Meter disables measurement to reduce power consumption during fatal faults.
Index 5
NET totalizer
Figure 7-10 Operator menu - Totalizer
Totalizer 3 indicates NET volume. For the CT version the totalizer is neither configurable nor
resttable.
Display test
Figure 7-11 Operator menu - Display test
All segments of display are alternately flashed on and off during this test.
Menu selection
6KRUWSUHVVIRUHQWHUHVFDSHPHQX
:DLWIRUPHQXV\PEROWRIODVK!VHF
Figure 7-12 Operator menu - Menu selection
If key is pressed shortly (2 to 5 seconds), menu selection will flash indicating that a new
selection can be made.
Operation
7.4 Operator menu
SITRANS MAG 8000
66 Operating Instructions, 11/2018, A5E03071515-AE