EasyManua.ls Logo

Siemens TC37 Module - AT^SMGL List SMS Messages from Preferred Storage

Siemens TC37 Module
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT Command Set
TC3X_ATC_01_V04.00 Page 158 of 204 29.05.2002
<mode> 0 unlock
1 lock
2 query status
<passwd> password
<class> integer or sum of integers each representing a <class> of information:
1 voice
2 data
4 fax
8 short message service
16 data circuit sync
32 data circuit async
64 dedicated packet access
128 dedicated PAD access
x combination of some of the above classes.
For example, the default setting 7 represents the sum of the
integers 1, 2 and 4 (call barring for voice, data and fax). The
value 255 covers all classes. If the <class> parameter is
omitted, the default value 7 is used.
See examples in 4.18.3 for the correct handling of class numbers.
<status> 0 off
1 on
Reference
Siemens
Note
See also specification of AT+CLCK in GSM 07.07 and further details in Chapter
4.18.
6.14 AT^SMGL List SMS messages from preferred storage
Test command
AT^SMGL=?
Response
See write command + CMGL
Parameters
See command +CMGL
Execute/Write
command
AT^SMGL
[=<stat>]
Response
TA returns messages with status value <stat> from message storage <mem1> to
the TE. The status of the messages is u n c h a n g e d (unread remains unread).
Otherwise: See command +CMGL
Parameters
See command +CMGL
Reference
Siemens
Note
See also GSM 07.05: +CMGL