AT Command Set
TC3X_ATC_01_V04.00 Page 68 of 204 29.05.2002
4.8 AT+CEER Extended error report
Test command
AT+CEER=?
Response
OK
Execute command
AT+CEER
TA returns an extended error report of the reason for the last call release and
location.
Response
+CEER: <location ID>, <reason > , <ss_release>OK
Parameter
<location ID> Location ID as number code (see subclause 7.1.5)
<reason> Reason for last call release as number code (see subclause
7.1.5)
<ss_release> Release cause for last Supplementary Service Call
(see subclause 7.1.13)
Reference
GSM 07.07
Note
· AT+CEER is not available for data calls, please use ATS18=1.