AT Command Set
TC3X_ATC_01_V04.00 Page 44 of 204 29.05.2002
3.2 AT+FBADMUL Error Threshold Multiplier
Read command
AT+FBADMUL?
This command defines the “Copy-Quality-OK” multiplier. The number of lines
received with a bad pixel count is multiplied by this number. If the result
exceeds the total number of lines on the page the error rate is considered too
high. A threshold multiplier value of 20 corresponds to a 5% error rate. A value
of 0 implies that error checking is not present or disabled.
Response
<badmul> OK
Parameter
See write command
Write command
AT+FBADMUL=
<n>
Response
OK
If error is related to ME functionality:
ERROR
Parameter
<n> 0 – 20 – 255
Reference
EIA PN-2388
Note
Used for Faxclass 2 only
3.3 AT+FBOR Query data bit order
Test command
AT+FBOR=?
Query the bit order for receive-mode. The mode is set by the ME dependent on
the selected Service Class, see “AT+FCLASS Fax: Select, read or test service
class”, pg. 45.
Response
(list of supported bit order modes <bor>s)
OK
Parameter
See write command
Read command
AT+FBOR?
Response
<bor> OK
Parameter
See write command
Write command
AT+FBOR=<bor>
Response
OK
Parameter
<bor> 0 direct bit order for both Phase C and for Phase B/D data.
1 Reversed bit order for Phase C data, direct Bit Order for
Phase B/D data.
Reference
EIA PN-2388
Note
Used for Fax class 2 only