AT Command Set
TC3X_ATC_01_V04.00 Page 36 of 204 29.05.2002
2.38 AT&V Display current configuration
Execute command
AT&V[<n>]
Response
TA returns the current parameter setting. The configuration varies depending on
whether or not PIN authentication has been done, or Multiplex mode has been
activated.
Parameter
<n> 0 profile number
PIN entered (see AT+CPIN, pg. 95) PIN not entered Configuration
without Multiplex
mode or
configuration on
channel 1 if
Multiplex mode
is enabled
ACTIVE PROFILE:
E1 Q0 V1 X4 &C1 &D2 &S0 \Q0
S0:000 S3:013 S4:010 S5:008 S6:000 S7:060
S8:000 S10:002 S18:000
+CBST: 7,0,1
+CRLP: 61,61,78,6
+CR: 0
+FCLASS: 0
+CRC: 0
+CMGF: 0
+CNMI: 0,0,0,0,1
+ILRR: 0
+IPR: 0
+CMEE: 0
^SMGO: 0,0
+CSMS: 0,1,1,1
^SACM: 0,"000000","000000"
^SCKS: 0,1
+CREG: 0,1
+CLIP: 0,2
+CAOC: 0
+COPS: 0,0,"operator"
OK
ACTIVE PROFILE:
E1 Q0 V1 X4 &C1 &D2 &S0 \Q0
S0:000 S3:013 S4:010 S5:008 S6:000 S7:060
S8:000 S10:002 S18:000
+CBST: 7,0,1
+CRLP: 61,61,78,6
+CR: 0
+FCLASS: 0
+ILRR: 0
+IPR: 0
+CMEE: 0
^SCKS: 0,1
OK
Logical channels
2 and 3
(Multiplex mode
enabled)
+CRC: 0
+CMGF: 0
+CNMI: 0,0,0,0,1
+ILRR: 0
+IPR: 19200
+CMEE: 0
^SMGO: 0,0
+CSMS: 0,1,1,1
^SACM: 0,"000000","000000"
^SCKS: 0,1
+CREG: 0, 1
+CLIP: 0,2
+CAOC: 0
+COPS: 0,0,"operator"
OK
+ILRR: 0
+IPR: 19200
+CMEE: 0
^SCKS: 0,1
OK
Reference
Note: Parameter values and order are subject to change.

Table of Contents