EasyManua.ls Logo

Siemens TC37 Module - AT^SSDA Set Display Availability

Siemens TC37 Module
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT Command Set
TC3X_ATC_01_V04.00 Page 178 of 204 29.05.2002
6.38 AT^SSDA Set Display Availability
Use the AT^SSDA command to specify whether your TC35 / TC37 product is designed to provide a
display. If there is one available, AT^SSDA enables or disables the mobile station to present
incoming Class 0 short messages directly on the display. The command is not required for other
short message Classes.
Test command
AT^SSDA =?
Response
^SSDA: (list of supported <da>s)
Parameter
See write command
Read command
AT^ SSDA?
Response
^SSDA: <da> OK
Parameter
See write command
Write command
AT^SSDA=
<da>
Response
OK
Parameter
<da>: display availability
0 the mobile station is not capable of displaying short messages
1 the mobile station is capable of displaying short messages
Please note that the setting is stored volatile, i.e. after restart or reset, the default
value 0 will be restored. Also, there is no way to store AT^SSDA to the user
defined profile.
Reference
Siemens
Note
If a mobile station is able to display short messages, class 0 messages shall be
displayed immediately. If the mobile station has no display, class 0 messages
shall be treated as though there was no message class.
Refer to GSM 03.38.
The setting of <da> influences the behaviour of the <mt> parameter in the
command AT+CNMI. This is the only effect of this command. If <da>=1 and
<mt>=1 or 3, then Class 0 short messages will be treated as if <da>=0 and
<mt>=2. For details on AT+CNMI refer to Chapter 5.10.
Multiplex protocol:
If using <da>=1 and <mt>=1 on one instance, all other instances have to use
<mt>=0.

Table of Contents