AT Command Set
TC3X_ATC_01_V04.00 Page 31 of 204 29.05.2002
2.28 ATS10 Set disconnect delay after indicating the absence of data carrier
Read command
ATS10?
Response
<n> OK
Write command
ATS10=<n>
This parameter setting determines the amount of time, that the TA remains
connected in absence of a data carrier. If the data carrier is detected before
disconnect, the TA remains connected.
Response
OK
Parameter
<n> 001-002-254 number of tenths of seconds of delay
Reference
V.25ter
Note
2.29 ATS18 Extended error report
Test command
ATS18?
Response
<n> OK
Execute command
ATS18=<n>
TA returns an extended report of the reason for the last call release and location.
<n> 0 – 255, odd numbers set extended error report and even
numbers disable this feature.
Response
+Cause: <location ID>: <reason > OK
Parameter
<location ID> Location ID as number code (see subclause 7.1.5).
<reason> Reason for last call release as number code (see subclause
7.1.5).
Reference
Siemens
Note
This command works for data calls only. For voice calls please use AT+CEER.
2.30 ATT Select tone dialling
Execute command
ATT
Response
OK
Reference
V.25ter
Note
No effect for GSM