AT Command Set
TC3X_ATC_01_V04.00 Page 159 of 204 29.05.2002
6.15 AT^SMGO Set or query SMS overflow presentation mode or query SMS
overflow
Test command
AT^SMGO=?
Response
^SGMO: (list of supported <n>s) OK
Parameter
See write command
Read command
AT^SMGO?
Response
TA returns overflow presentation mode and SMS overflow status
^SGMO: <n>,<mode> OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameter
See write command
Write command
AT^SMGO=<n>
Response
TA sets overflow presentation mode
OK
Parameter
<n> SMS overflow presentation mode
0 disable (default)
1 enable
<mode> SMS overflow status
0 space available
1 SMS buffer full (SIM card)
2 Buffer full and new message waiting in SC for delivery to phone
Unsolicited result code
When the status SIM overflow changes, an unsolicited result code is sent to TE
^SMGO: <mode>
Parameter
See write command
Reference
Siemens
Note
Indication during data transfer via break (100ms). Data transmission will only be
interrupted by a break and for only 100ms.