Communication via SIKONETZ5
AG05
Date: 15.06.2016 Art. No. 85677 Mod. status 139/16 Page 56 of 64
10.8.6 Flow chart: Operating mode: Speed mode
Fig. 11: Flow chart speed mode SIKONETZ5
10.9 Parameterization via SIKONETZ5
On principle, the actuator sends a telegram acknowledging write and read commands of the
master. With the command executable the value adopted is in the reply telegram.
If the actuator was unable to execute the command, e. g. because it attempted to write a
value beyond the admissible range, the actuator will send an error telegram in reply.
Access
rw = read write
ro = read only
wo = write only
Operation enabled
SW = 0000 x001 00x0 00x1
Enable operation
CW = 0000 0000 0000 0111
Ready to travel
SW = 0000 x001 00x0 0011
Enable target value
CW = 0000 0000 0001 0111
Set point enabled
SW = 0000 x101 01xx 0001
Change set point
CW.4 = 1
Disable set point
CW.4 = 0
Error
SW.7 = 1
Acknowledge error
CW.5 = 1
Switch lock
SW.9 = 1
OFF1 CW.0 = 1/0 or
OFF2 CW.1 = 1/0 or
OFF3 CW.2 = 1/0
Start
Supply voltage ON
CW = 0000 0000 0000 0000
CW = Control word SIKONETZ5
SW = Status word SIKONETZ5
x = Bit can be '0' or '1'