EasyManua.ls Logo

SimpliVity OmniCube CN-2000 - About Hardware Upgrades

SimpliVity OmniCube CN-2000
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CN-Series Hardware Installation and Maintenance Guide About Hardware Upgrades
Specification Maximum System Limit
Vibration (operating) 0.26Grms at 5-350Hz in all orientations.
Vibration (storage) 1.87Grms at 10-500Hz for 15 minutes (all six sides tested).
Shock (operating) One shock pulse in the positive z axis (one pulse on each side of the system) of 31G +/–
5% for +/10%; in the operational orientation.
Shock (storage) Half sine shock on all six sides of 71G +/ 5% with a pulse duration of 2ms +/10%;
square wave shock on all six sides of 27G with velocity change at 235 in/sec or greater.
Altitude and Airborne Contaminants
The following table describes the maximum altitude and airborne contaminants specifications for all
CN-Series system models.
Specification Maximum System Limit
Altitude (operating) -15.2m to 3048m (–50 ft to 10,000 ft)
Altitude (storage) -15.2m to 12,000m (–50 ft to 39,370 ft)
Contaminant level (operating) Class G1 or lower as defined by ISA-S71.04-1985
Agency Compliance
The following table lists agency compliance for all CN-Series systems.
Standard
FCC47 CFR Part 15 Subpart B: 2012
EN 55022:2010 COR 2011
CISPR 22:2008
EN 55024:2010
CISPR 24:2010
COR 2011
VCCIV3:2009
ANSI/UL 60950-1, 2nd Edition (2007)
CSA C22.2 No. 60950-1 2nd Edition (2007)
IEC 60950-1:2005 (2nd Edition); Am 1:2009
RoHS EU Directive 2002/95/EC
About Hardware Upgrades
If you would like to upgrade the system hardware components, contact SimpliVity Customer Service.
Warning: Never install additional options in the other than those approved for installation by
SimpliVity. Doing so will void your warranty and might cause serious system instability and
potential data loss.
13

Table of Contents

Other manuals for SimpliVity OmniCube CN-2000

Related product manuals