Robertson AP45 Autopilot
Technical specifications
Simrad Robertson AS
Egersund - Norway
Page 4-5
Dimensions:................................................See Fig. 4-5.
Cable length: ..............................................2 m (with plug)
Ambient temperature, storage:............–25 - +70°C
operation: .......–10 - +55°C
Input signal: ...............................................sine/cosine
Output signal:.............................................sine/cosine ±2V DC at +2.5V reference
89 (3.5")
47 (1.85")
3.5 (0.14")
160 (6.3")
144 (5.67")
34 (1.34")
148 (5.83")
25 (0.98")
Fig. 4-5
FI100-40 Fluxgate Interface - dimensions
Dimensions: ................................................See Fig. 4-6.
Protection:...................................................IP56
Ambient temperature: ...............................–10 - +55°C
Operating voltage:......................................12V DC (autopilot supplied)
Frequency output, Feedback: ....................3400Hz (midship reference)
Port: +20Hz/degree, stbd: -20Hz/degree
Current output, Indicator..........................0.1mA - 1.1mA
Capacity:.....................................................5 indicators in series
Rudder angle: .............................................±45°
Cable length:...............................................2 m (6 ft)
Fig. 4-6
RF45X Rudder Feedback - dimensions
FI100-40 Fluxgate
Interface
RF45X Rudder
Feedback Unit