© Jan 2022 6-24 0607SE Maintenance Manual
REPAIR
Update program
Note: Updating the program will restore all system
settings debugged by the original machine owner/user/
Sinoboom to the original settings set by the control
system manufacturer. Therefore, it is prohibited to
update the program without the authorization of
Sinoboom. If you need to update the program, please
contact Sinoboom after-sales personnel.
Check program version
When the machine is powered on, the screen will
display the current program version in the first 2s of
startup. If “A4” is displayed, the program version is
correct.
Figure 6-29
Set Speed
In the “1.Set Speed” menu, the Max Fast Speed, Max
Low Speed, Max Raised Speed, Max Lift Speed, Max
Steer Speed and Steer Boost can be set.
Set option
In the “2.Set Option” menu, the Machine Type, Load
Sensor Mode and Pressure Sensor Mode can be
selected.
In the “2.Set Option” menu, the Drain Alarm Time,
Drain Shut Time can be set.
In the “2.Set Option” menu, the Pothole Guard,
Descent Delay, Motion Alarm, Load Sensing, High
Torque, Limit Drive, Foot Pedal, Anti-collision and
BMS Function can be switched on or off. However,
the Pothole Guard, Load Sensing and Motion Alarm
functions are switched on by default. Even if these
functions are turned off manually, they will return to
the default ON state when the machine is powered
on again.
Calibrate joystick
Ensure the joystick is in neutral position before power-
on.
Calibrate weight and height
NOTICE
The height calibration will be carried out
automatically while the weight calibration is
performed.
Weight calibration includes no-load calibration
and full-load calibration. Please complete the
calibration with the ECU panel within one cycle as
per the following procedures.
No-load calibration (& height calibration)
1. Lower the platform to the stowed position, and
ensure that the space above the platform allows
the platform to be safely lifted to the maximum
height.
2. Make sure no heavy objects are placed on the
platform.
3. After entering the ECU menu selection mode,
select and enter Calibration interface, and press
the Enter key for confirmation.
Figure 6-30
4. When the screen displays “Execute No Load
Calibration?”, press the Enter key for 5s to start
automatic no-load calibration.
Figure 6-31
5. The platform will rise and descend for three
times automatically: rise to the highest position
and descend to the stowed position (the first,
second and third ascending and descending
movements are for height calibration, static
calibration and dynamic calibration respectively).
6. When the screen displays “No Load Calibration
Complete!”, the no-load calibration (& height
calibration) is successfully done.
Figure 6-32
7. Return to the Calibration interface through the
Esc key.
Full-load calibration
1. Place heavy objects with the same weight as the
rated load of the machine on the platform.
2. Select and enter Execute Full Load Calibration?
interface, and press the Enter key for 5s to start
automatic full-load calibration.
A4
Calibration
Execute No Load
Calibration?
No Load Calibration
Complete!
Execute Full Load
Calibration?

Table of Contents