EasyManua.ls Logo

Sinoboom 0607SE - Page 96

Sinoboom 0607SE
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Jan 2022 6-32 0607SE Maintenance Manual
REPAIR
Code Problem Action Limit Solution
27
Sharp Difference in
Temperature
Disable Lifting and Driving
Sharp Difference in Temperature: Inform BMS
factory to check battery.
28
Discharge Current
High Fault 2
Disable Lifting and Driving
Discharge Current High Fault 2: Inform BMS
factory to check battery.
29
Discharge
Temperature Fault 2
Disable Lifting and Driving
Discharge Temperature Fault 2: Inform BMS
factory to check battery.
31
Pressure Sensor 1
Fault
Disable All Motion
Pressure Sensor 1 Fault: Check the wiring to the
sensor and then the sensor itself. Also check to
make sure that the correct option is properly
selected (or not) for load sensing.
32
Angle Sensor Fault
Disable All Motion
Angle Sensor Fault: Check the wiring to the sensor
and then the sensor itself. Also check to make
sure that the correct option is properly selected (or
not) for angle sensing.
35
Pressure Sensor 2
Fault
Disable All Motion
Pressure Sensor 2 Fault: Check the wiring to the
sensor and then the sensor itself. Also check to
make sure that the correct option is properly
selected (or not) for load sensing.
36
Battery Drain Alarm Lift Slow to Drive Speed
Battery Drain Alarm: Battery voltage is low, charge
the battery.
37
Battery Drain
Shutdown
Disable All Motion
Battery Drain Shutdown: Battery enters into sleep
mode, and operate the joystick or button on ECU
controller to quit the mode.
42
Platform Left Button
ON
Diagnostic Message Only
Platform Left Turn Switch ON at power-up
Message: Ensure that nothing is holding the
Joystick Toggle Switches down. If OK, consider
replacing the Joystick or PCU.
43
Platform Right Button
ON
Diagnostic Message Only
Platform Right Turn Switch ON at power-up
Message: Ensure that nothing is holding the
Joystick Toggle Switches down. If OK, consider
replacing the Joystick or PCU.
46
Platform Enable
Button ON
Disable Platform Control
Platform Joystick Enable Switch ON at power-up
Fault: Ensure that nothing is holding the Enable
switch closed. Also check the neutral zone
parameters. If OK, consider replacing the Joystick
or PCU.
47
Joystick Not In
Neutral
Lift Slow to Drive Speed
Platform Joystick not in neutral at power-up
Message: Make sure that the Joystick is in the
neutral (upright) position. Check the neutral zone
parameter setting in the LabView Programmer. If
it’s OK, consider replacing the Joystick or the
PCU.
52 Forward Coil Fault
Disable Lifting and Driving
Forward Coil Fault: Check the connections to the
Coil’s terminals and make sure they are tight. If so,
check the coil itself to see if it is open or shorted.
53 Reverse Coil Fault
Disable Lifting and Driving
Reverse Coil Fault: Check the connections to the
Coil’s terminals and make sure they are tight. If so,
check the coil itself to see if it is open or shorted.