Section 04 ENGINE
Subsection 08 (LIQUID COOLING SYSTEM)
04-08-5
Skandic WT LC
Open cap and fill filler neck
no. 8
completely.
Tilt seat and unscrew bleeding screw on top of
connecting hose. Coolant must flow. Refill
through filler neck
no. 8
as necessary.
Reinstall bleeding screw.
Proceed the same for bleeding screw on thermo-
stat housing.
Start engine and let it warm until thermostat
opens.
To make sure coolant flows through radiators,
touch them by hand. They must feel warm.
Turn engine off. Let it cool down for 15 to 20 min-
utes.
Open cap and refill filler neck completely.
Start engine and let it idle. Do not race engine.
If coolant level gets down, add more coolant in
filler neck.
Turn off engine and close cap.
IMPORTANT:
After first drive let engine com-
pletely cool down. Check that coolant level is at
top of filler neck. Add coolant as necessary. This
is to ensure that coolant circulation from and back
to overflow coolant tank works properly. Overflow
coolant tank should be half full when engine is
cold.