EasyManua.ls Logo

Ski-Doo Summit 583 1998 - Inspection of Heating Elements

Ski-Doo Summit 583 1998
398 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 06 ELECTRICAL
Subsection 06 (TESTING PROCEDURE)
06-06-16
INSPECTION OF HEATING ELEMENTS
All Models Except Skandic WT/SWT/WT LC
All measurements must be performed at 21°C
(70°F).
Throttle Lever Heating Element
Resistance Measurement
Current Measurement
Handlebar Grip Heating Element
Resistance Measurement
Skandic WT/SWT/WT LC
Throttle Lever Heating Element
Resistance Measurement
Handlebar Grip Heating Element
Resistance Measurement
➀
When measuring resistance at terminals the
actual value will be half the measurement in
table. The reason for that is the elements are
connected in parallel. Therefore the total resis-
tance is half the resistance of one element.
HIGH
INTENSITY
YELLOW
/
BLACK wire
BROWN wire
1.96 to
3.64 ohms
LOW
INTENSITY
YELLOW
/
BLACK wire
BROWN
/
YELLOW wire
8.05 to
14.95 ohms
HIGH
INTENSITY
BROWN wire
0.23 A
minimum
LOW
INTENSITY
BROWN
/
YELLOW wire
0.13 A
minimum
HIGH
INTENSITY
YELLOW
/
BLACK wire
ORANGE wire
8.73 to
➀
10.67 ohms
LOW
INTENSITY
YELLOW
/
BLACK wire
ORANGE
/
VIOLET wire
17.7 to
➀
20.7 ohms
BLACK wire
BLACK wire
48 ohms
BLACK wire
BLACK wire
9.6 ohms
➀

Table of Contents