Installation
Service Manual
SKOPE Reflex Underbench Fridge and Freezer
3 Installation
Installation Guidelines
When installing this cabinet, ensure you consider and meet the installation guidelines.
Ventilation Requirements
This cabinet must have the following ventilation clearances at all times:
*When installed for continuous duty in climate class 7 environment (35°C ambient/
75% relative humidity), SKOPE recommends providing 50 mm clearance around the sides
and back of the cabinet.
Ventilation
Ensure all ventilation
requirements below
are met.
Door Opening
Allow adequate
space for the door/s
to open and close
properly.
Sunlight
Do not install the
cabinet in direct
sunlight.
Uneven Surface
Do not install the
cabinet on an uneven
surface.
Surface
The installation
surface must be
capable of
supporting the
loaded cabinet.
Power Supply
Do not overload the
power supply.
Blocking Ventilation
Do not store boxes or
items in front or on top
of the cabinet.
Climate Class
The cabinet must be installed in
an environment within its
climate class.
The climate class is stated on
the cabinet rating label inside
the cabinet.
No below clearance required
Min. 300mm above
No side
clearance
required
No behind
clearance
required
No side
clearance
required
No behind
clearance
required
No below clearance required
No above clearance required
Upright Cabinets Underbench Cabinets
Keep area in front of grille
and doors/drawers clear
Keep area in front
of doors clear
*
*
*
*
No below clearance required
Min.100 mm
left side
Keep area in front of
grille and drawers clear
ChefBase Cabinets
No behind
clearance
required
*