SLAYER STEAM LP USER MANUAL V1.1 | JUNE 2019 23
4. Scroll to select Advanced, and repeat step 3 for the Advanced
password.
5. Long press and hold the menu button to save and exit back to the
Home screen
PROTIP: Write down the passwords
Manager ________________________
Advanced ________________________
Disable Passwords: Manager & Advanced Menus
Caution: Disabling Passwords will allow any user to change
settings in the Advanced Menu
To Disable all Passwords:
1. From the Home menu scroll to the Enter Password prompt
2. Scroll to select <DISABLE> and press the menu button to enter.
To Disable the Manager Password Only:
1. From the Home Screen scroll to Enter Password or Menu Prompt and
press the menu button.
2. Enter the Password you previously set for the Advanced Menu; from
the Advanced Menu scroll to Password and press the button. Select
<ENABLE> and then scroll to select <Manager>.
3. Scroll to the first slot for character to the numerical value 0, one more
click counterclockwise to a blank space or <null> value between the
brackets; Ex. < >
4. Press to select and the password for that menu is now set to null
NOTE: Setting the Advanced password to <null> (o) disables
programming a password for the Manager menu.
PROTIP: Hold the button for 2 seconds to go back to the last
screen, and 5 seconds to return to the home menu.
The Home Display Menu is rich with real time details on multiple
functions within the machine.
• Heating element activity, represented by a colon (“:”). When a brew
tank is being heated, the colon will flash near the brew temperature
reading on the corresponding screen.
• Steam tank fill status, represented by an upward-facing arrow. When
the steam tank is being filled, the arrow will appear next to the steam
tank pressure reading.
• Brew time (“Time”) for the previous extraction, displayed in tenth-
second (0.1-second) increments. At the beginning of each extraction,
the timer will automatically reset and begin counting up from zero (0).
At the end of each extraction, the timer will automatically stop and
will remain visible until the next extraction begins. Button activations
under 2 seconds will not reset the shot time, and under 5 second will
not count as a shot in the shot counter. This is to allow the barista an
opportunity to flush or purge the group after an extraction and still see
the value of your previous extraction.
• Last Shot Weight (“Wt”) reading, displayed to the nearest tenth of a
gram
• Brew temperature (“Temp”) reading, displayed in tenth-degree
(0.1-degree) increments in Fahrenheit or Celsius.
• Steam tank pressure (“Stm”) reading, displayed in 0.1-bar increments.
MENU OPTIONS
The first level of navigation is the Default Display menu which houses
several options for easy access:
1. Default Display:
Extraction Time, Shot Weight, Temperature (& Steam Pressure)
2. Quick Change Last Shot Parameters
3. Manual Button Default Parameters
4. (Deeper) Menu Options
5. Shot Counter
6. Group Cleaning-Full Clean
7. Group Cleaning-Quick Clean
8. Switch O
PROTIP: Scrolling counter clockwise intentionally showcases the Group
Cleaning - Quick and Full to encourage cleaning whenever possible.
Default Display: Group Settings
SCREEN EXAMPLE:
Time Wt Temp Stm:
25.2s 30.6g 199.0 1.4↑
The last espresso brew shot time and weight is noted on the left half of
the screen. Group Temperature is displayed on the right side and Steam
Pressure is displayed on the far right of the Group 1 screen only. Note that
the shot timer does not reset unless it runs for longer than two seconds.
This allows the barista to purge the group of residue and not lose sight of
the previous shot time.