Technical documentation
4.1 Max. number of equipment modules in an IPM server
Type of
module
IPM-032.WM.A IPM-032.WM.L IPM-032.2U.A IPM-032.2U.L
Remark
Max. number of
ports
Max. number
of ports
Max. number of
ports
AB 24 (6x4) 24 (6x4) 32 (8x4) 32 (8x4)
CTS 124
3
124
3
124
3
124
3
Together with
CTS.IP
ISDN BRA
4
12 (6x2) 12 (6x2) 16 (8x2) 16 (8x2)
POTS 12 (6x2) 12 (6x2) 16 (8x2) 16 (8x2)
GSM 12 (6x2) 12 (6x2) 16 (8x2) 16 (8x2)
E1 2 - 2 -
IPM32VOIP 2 - 2 -
IPM2RL2SN 24 (6x4) 24 (6x4) 32 (8x4) 32 (8x4)
3 Including max. 6 IPM4CTS (WM) cards and 8 IPM4CTS (2U) cards
4card ports can be used as external or internal ones