- 96 -
No.SFOD-OMT0010-B
11. The Speed/ pushing force may vary, depending on the cable length, load and mounting
conditions etc.
If the cable length exceeds 5m, the speed/ pushing force will decrease by a maximum of 10% per 5m.
(If cable length is 15m: Maximum 20% reduction.)
[Transport]
Caution
1. Do not carry or swing the product by the motor or the cable.
13. Electric Actuators / Common Precautions
13.1 Design and Selection
Warning
1. Read the Operation Manual before using the product.
Handling or usage/operation other than that specified in the Operation Manual may lead to
breakage and product failure.
Any damage attributed to use beyond the specifications is not guaranteed.
2. There is a possibility of dangerous sudden action by the product if sliding parts of
machinery are twisted due to external forces, etc.
In such cases, human injury may occur, such as catching hands or feet in the machinery, or damage
to the machinery itself may occur. The machinery should be designed to avoid such dangers.
3. A protective cover is recommended to minimize the risk of personal injury.
If a driven object and moving parts of the product are in close proximity, personal injury may
occur. Design the system to avoid contact with the human body.
4. Securely tighten all stationary parts and connected parts so that they will not become
loose.
When the product operates with high frequency or is installed where there is a lot of vibration,
ensure that all parts remain secure.
5. Consider a possible loss of power source.
Take measures to prevent injury and equipment damage in the case of a power supply failure.
6. Consider the behavior of an emergency stop of the whole system.
Design the system so that human injury and/or damage to machinery and equipment will not
be caused, when it is stopped by a safety device for abnormal conditions such as a power
outage or a manual emergency stop of the whole system.
7. Consider the action when operation is restarted after an emergency stop or abnormal
stop of the whole system.
Design the system so that human injury or equipment damage will not occur upon restart of
operation of the whole system.
8. Prohibition of Disassembly and Modification
Do not disassemble the product or make any modifications, including additional machining.
This may cause human injury and/or an accident.
9. Do not use the controller stop signal, "EMG" as an emergency stop for the system.
The controller stop signal "EMG" is to be used only for decelerating and stopping the actuator.
Design the system with a separate emergency stop circuit which conforms with the relevant safety
standards.
10. When using for vertical applications, it is necessary to build in a safety device.
The rod may fall due to the weight of the work.
The safety device should not interfere with normal operation of the machine.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks JXC73 Series and is the answer not in the manual?

SMC Networks JXC73 Series Specifications

General IconGeneral
BrandSMC Networks
ModelJXC73 Series
CategoryController
LanguageEnglish

Related product manuals