- 44 -
No.SFOD-OMT0010-B
6.4 Parallel I/O Wiring Example
The Wiring depends on the parallel input/output type of the controller (NPN or PNP).
(1) NPN type
Caution
Prepare a separate power supply for the main control, motor drive and motor control and input/ output
signal.
I/O 1
OUT0
10
OUT1
30
OUT2
11
OUT3
31
OUT4
12
OUT5
32
OUT6
13
OUT7
33
OUT8
14
BUSY
(OUT9)
34
AREA
(OUT10)
15
SETON
35
INP
16
SVRE
36
ESTOP
17
ALARM
37
-COM1
18
-COM1
19
-COM1
38
-COM2
20
-COM2
39
-COM2
40
+COM1
1
+COM2
21
IN0
2
IN1
22
IN2
3
IN3
23
IN4
4
IN5
24
IN6
5
IN7
25
IN8
6
IN9
26
IN10
7
SETUP
27
HOLD
8
DRIVE
28
RESET
9
SVON
29
24 VDC
Load
Load
Load
Load
oad
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load

Table of Contents