Snap‐onEEWB330AHandspinWheelBalancer
CodeC14
Balancerrecalibrationbytheuser.Ifseveralmeasuring
runsarenecessarytobalanceawheelbecausebalance
weightsizeandpositionhavetobereadjusted
repeatedly,thisisoftenduetoinsufficient
measurementaccuracy.
Balanceawheel,settingthetypeasNORMAL,withless
than5gramsperplane.Checkin“fine”mode.Gointo
codeC14.
“CAL1”appearsandthemachinebeeps.Performthe
wheelmeasuringrun.Attheendthedisplayshows
“CAL2”.ScrewontheUserCalibrationWeight,asshown
inFigure6‐2.Performthewheelmeasuringrun.Atthe
endthedisplayappearsasshowninFigure7‐3to
indicatethatcalibrationwasperformedcorrectly.
Note:Anyerror(bytheoperator)closestheprogram.
ErrorcodesarelistedinSection7.1.2.
*=Factoryadjustedmode