The Scope and Multimeter module enables the VERDICT to function as a digital multimeter
(DMM), a graphing multimeter, and a 2-channel oscilloscope when the Display Device is
wirelessly linked to the Data Acquisition Device.
9.1.1 Capabilities
The following tables detail the software and hardware capabilities.
Table 9-1 Multimeter
Function Range Resolution Accuracy
Impedance/
Protection
Volts DC
40mV 0.01mV
±(1.0% of reading + 3 digits)
10M Ohm
400mV 0.1mV
4V 0.001V
40V 0.01V
400V 0.1V
1000V 1V ±(1.5% of reading + 3 digits)
Volts AC
400mV 0.1mV
±(1.5% of reading + 4 digits)
10M Ohm
4V 0.001V
40V 0.01V
400V 0.1V
±(2.0% of reading + 4 digits)
1000V 1V
Resistance
40 Ohm 0.01 Ohm ±(0.75% of reading + 5 digits)
600V DC
or Peak AC
400 Ohm 0.1 Ohm
±(0.5% of reading + 3 digits)
4k Ohm 0.001k Ohm
40k Ohm 0.01k Ohm
400k Ohm 0.1k Ohm
4M Ohm 0.001M Ohm
±(0.75% of reading + 5 digits)
40M Ohm 0.01M Ohm
Capacitance
40nF 0.01nF
±(3.0% of reading + 15 digits)
600V DC
or Peak AC
400nF 0.1nF
4uF 0.001uF
40uF 0.01uF
400uF 0.1uF
4mF 0.001mF
±(5.0% of reading + 15 digits)
40mF 0.01mF
Frequency
40Hz 0.01Hz
±(0.5% of reading + 2 digits) N/A
400Hz 0.1Hz
4kHz 0.001kHz
40kHz 0.01kHz
400kHz 0.1kHz
2MHz 0.001MHz
Duty Cycle 0.1 — 99.9% 0.1% N/A N/A
Pulse Width 0.1 — 99.9% 0.1% N/A N/A
Diode Test 3V* N/A Range = 2V N/A
Continuity 3V* N/A Threshold = 0.1% N/A
* Test voltage.