66
Pin
Colour
Function
7
brown/white
Internally shorted
8
brown
Logic interface for VDE-AR-N 4105:2018-11
This function serves to control and/or limit the output power of
the inverter.
The inverter can be connected to a radio ripple control receiver
in order to dynamically limit the output power of all inverters
within the system.
Figure. 5-37 Logic interface(a)
The inverter is preconfigured on the following power levels:
Table. 5-17 Logic interface description(a)
Pin
Name
Inverter
Radio ripple control
receiver
1
L1
Relay 1 input
K1 - output relay 1
2
L2
Relay 2 input
K2 - output relay 2
3
L3
Relay 3 input
K3 - output relay 3
4
L4
Relay 4 input
K4 - output relay 4
6
G
Ground
Relay, common ground