HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
86
“System Settings” menu
In this menu you can do the basic settings which are needed to
operate the device.
1. Language Settings
Sets the display language
2. Time
Sets the system time of the inverter
3. Safety Param.
Sets the country and grid code
4. Energy Storage
Mode
Select between Self-use mode
(Standard), time-of-use mode, timing
mode, passive mode. See “Storage
Modes” chapter for details.
5. Input Channel Config
With the Input Channel Configuration
you define if PV and / or batteries are
connected and in what configuration.
Bat Channel1
If a battery is connected to BAT1
input, select “Bat Input1”, otherwise
“Not Use”
Bat Channel2
if a second battery is connected to
BAT2 independently, select “Bat
Input2”
If one battery is connected in parallel
to BAT1 and BAT2, select “Bat Input1”,
otherwise “Not Use”
PV Channel1
if PV strings are connected to PV1
independently, select “PV Input 1”,
otherwise “Not Use”
PV Channel2
if PV strings are connected to PV2
independently, select “PV Input 2”
If PV strings are connected to PV2 in
parallel to PV1, select “PV Input 1”,
otherwise “Not Use”
6. EPS Mode
Enable / Disable the emergency
power supply mode (EPS). It is only
available if a battery is connected
7. Communication
Addr.
Enter the Modbus address (when
several inverters require simultaneous
monitoring), standard: 01
Baud Rate: The default baud rate is
9600