HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
“Advanced Settings” menu
Password
Several settings require a password to be entered (the
standard password is 0001).
In this menu you can do advanced settings.
Set the battery parameters for
Battery 1 and Battery 2.
Depending on the selected
Battery Type, more settings can
be adjusted. See details below.
Automatic battery configuration
(only available for SOFAR battery
types). Detects all battery
modules and the assignment to
the battery inputs.
Set the capacity of connected
battery
(only for batteries with
integrated BMS)
Up to 4 battery addresses for
each Battery Input Channel can
be set. This is the CAN bus or
Modbus ID of each battery stack
connected to the Battery Input,
depending on the bus type
between inverter and the BMS.
Nominal Battery Voltage
(V)
Nominal DC voltage of the
battery
(for inverter-integrated BMS)
Max. Charging Current (A)
Max. allowed charging current
for the battery
Max. allowed discharging current