HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
Max. allowed discharge depth
(DOD) for the battery. DOD of
80% means, a battery with 10
kWh capacity can be discharged
to a minimum energy level of 2
kWh.
Max. Depth of Discharge (DOD)
for grid-connected mode.
Standard 80%.
When setting the BTS-5K battery
discharge depth, the maximum
limit is 90% to prevent the
battery from being too low to
recharge.
Depth of Discharge (DOD) for
EPS mode. Standard: 80%
State of charge (SOC), where the
battery will be recharged in EPS
mode. Standard: 20%
Define the time for the forced
charge. Forced charging takes
place when the SOC of the
battery falls below 8%.
1.2 Auto Configure
Address
Select "Auto configure address",
you can see "Battery quantity"
after entering, and you can
configure the quantity by
yourself
Enable / disable.
If Automatic activation is
enabled, the inverter will activate
the battery when the inverter
need to discharge or charge the
battery according to the
operational mode settings.
If automatic activation is
disabled, the battery has to be
activated manually by selection