HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
89
the “Force active” menu item.
Force Active
Select “Force active” to activate a
battery from standby mode
3. Set Feed-in Limit
Activates or deactivates the feed-
in power function of the inverter
and sets the maximum feed-in
power. This function must be
used together with an external
current transformer or the smart
meter. Details regarding this can
be found in the
“Communications interfaces”
chapter of this manual
Feed-in Limit
Disable: Do not use this function
Three phase limit: the sum of all
phases is regulated (balancing
counting as is common in
Germany).
Feed-in Limit: the power of the
feeding-in phases is limited.
4. IV Curve Scan
Cyclical scanning of the IV curve
in order to find the global point
of the maximum output.
Advisable in the case of shaded
solar generators
Scan Control
Enable / disable IV curve scan
function
Scan Period
Set scan period in minutes
Force Scan
Manually start IV curve scanning
5. Logic Interface
Activates or deactivates logical
interfaces. Details regarding this
can be found in the
“Communications interfaces”
chapter of this manual
6. Restore Factory Settings
Resets stored data in the inverter
Clear Energy Data
Clears total power production
Clear Events
Clears historical events
Restore Factory Settings
Clears total power production
and historical events
7. Parallel Setting
Defines configuration for parallel