HYD 5/6/8/10/15/20KTL-3PH USER MANUAL
* Function 12,13 are available from firmware version V10.
The inverter (Available from hardware version V003)
has built-in relays to control the short circuit of
the load N line to ground when off-grid.
When the inverter is off-grid and the load N line and
PE line are short-connected, if the power grid is
restored and the load N line and PE line are still
short-connected, leakage protection will be triggered
and explosion hazard will not be caused.
“Energy Statistics” menu
Press Down button to move between
items
Shows PV, Load, Export, Import,
Charge, Discharge Energy (kWh) for
the selected period
“System Information” menu
Serial number, Power Level
Software Version(To view the software
version, enter password 0001), Country,
Country Code Version
Bat Channel1, Bat Channel2, PV
Channel1, PV Channel2
Energy Storage Mode, RS485 Address,
EPS Mode, IV Curve Scan
DRM0 Control, PF Time Setting, QV
Time Setting, Power Factor
Feed-in Limit, Insulation resistance,
Parallel Control, Unbalanced Support