Technical Data
18
19
Technical Data
3.3 Battery
Battery type
Battery Full Voltage [V]
Maximum charge/discharge flow [A]
Communication interface
Reverse connection protection
Lithium batteries
80-480
30A
CAN/RS485
Yes
X1-Hybrid-3.0-D
Model
X1-Hybrid-3.0-M
X1-Hybrid-3.7-D
X1-Hybrid-3.7-M
X1-Hybrid-5.0-D
X1-Hybrid-5.0-M
Integrated(TypeIII)
Integrated(TypeIII)
YES
YES
YES
YES
YES
YES
YES
YES
YES
3.4 Efficiency, Safety and Protection
MPPT efficiency
European efficiency
Maximum efficiency
X1-Hybrid-3.0-D
Model
X1-Hybrid-3.0-M
X1-Hybrid-3.7-D
X1-Hybrid-3.7-M
X1-Hybrid-5.0-D
X1-Hybrid-5.0-M
99.9%
97.0%
97.6%
97.0%
99.9%
97.0%
97.6%
97.0%
99.9%
97.0%
97.6%
97.0%
Max. battery charge efficiency
(PV to BAT )(@ full load)
Max. battery discharge efficiency
(BAT to AC)(@ full load)
97.0% 97.0% 97.0%
X1-Hybrid-6.0-D
X1-Hybrid-6.0-M
X1-Hybrid-6.0-D
X1-Hybrid-6.0-M
99.9%
97.0%
97.6%
97.0%
97.0%
X1-Hybrid-7.5-D
X1-Hybrid-7.5-M
X1-Hybrid-7.5-D
X1-Hybrid-7.5-M
99.9%
97.0%
97.6%
97.0%
97.0%
Security & Protection
DC SPD Protection
AC SPD Protection
Over/under voltage protection
Grid protection
DC injection monitoring
Back feed current monitoring
Residual current detection
Anti-islanding protection
Over load protection
Over heat protection
Array insulation resistance detection
3 Technical Data
3.1 DC Input
3.2 AC Output/Input
Max. recommended PV power[W]
Max. DC voltage[V]
Nominal DC operating voltage[V]
MPPT voltage range[V]
MPPT Full Powervoltage range [V]
Max. input current[A]
Max. short circuit current[A]
Start output voltage[V ]
No. of MPP trackers
Strings per MPP tracker
4500
600
360
115-480
14/14
16/16
90
2
1
X1-Hybrid-3.0-D
Model
X1-Hybrid-3.0-M
X1-Hybrid-3.7-D
X1-Hybrid-3.7-M
X1-Hybrid-5.0-D
X1-Hybrid-5.0-M
5500
600
360
135-480
14/14
16/16
90
2
1
7500
600
360
70-550
190-480
14/14
16/16
90
2
1
Rated AC voltage[V]
Rated grid frequency[Hz]
Displacement power factor
Total harmonic distortion( THDi)
3000
3300
X1-Hybrid-3.0-D
Model
X1-Hybrid-3.0-M
X1-Hybrid-3.7-D
X1-Hybrid-3.7-M
X1-Hybrid-5.0-D
X1-Hybrid-5.0-M
3680
3680
5000(Germany
4600AU4999)
5500(Germany
4600AU4999)
23.9(Germany20,
AU21.7)
AC Output
220/230/240 (180 to 270)
50/60
0.8 leading...0.8 lagging
< 2%
AC Input
6300
3000
7360
3680
9200
5000
220/230/240 (180 to 270)
50/60
0.8 leading...0.8 lagging
Max. apparent power[VA]
Rated AC power[W]
Rated grid voltage(range)[V]
Rated grid frequency[Hz]
Max.AC current[A]
Displacement power factor
X1-Hybrid-6.0-D
X1-Hybrid-6.0-M
9000
600
360
225-480
14/14
16/16
90
2
1
X1-Hybrid-6.0-D
X1-Hybrid-6.0-M
6000
6600
9200
6000
4040
27.4
32
X1-Hybrid-7.5-D
X1-Hybrid-7.5-M
10000
600
360
280-480
14/14
16/16
90
2
1
X1-Hybrid-7.5-D
X1-Hybrid-7.5-M
7500
7500
9200
7500
40
32.628.616
14.4
Max. apparent AC
power[ VA]
Nominal AC power[ VA]
Max.AC current[A]