100
8.2 Routine Maintenance
Inverters do not require any maintenance or correction in most cases, but if
the inverter often loses power due to overheating, this can be attributed to
the following reason:
If necessary, clean the cooling heat sink with a soft dry cloth or brush.
Only trained and authorized professionals familiar with safety requirements
can perform maintenance and maintenance work.
Ø
Regular maintenance
Ø
BMS_BreakFault
Battery Unbalanced Failure
• Please contact the battery supplier.
BE 027
BMS_Flash_Fault
Battery hardware protection failure
Please contact the battery supplier.
BE 028
BE 029
BE 030
BMS_Precharge_Fault
BMS_AirSwitch_Fault
Number
if the information panel of your inverter does not show the fault light, check
the following list to ensure the current installation status, correct operation.
------Is the inverter located in a clean, dry and well-ventilated place?
------Is the DC input circuit breaker open?
------Is the specification and length of the cable adequate?
------Are the input and output connections and wiring in good condition?
------Is the configuration set correct for your particular installation?
BMS_TempdiffErr
Battery temperature sensor malfunction
Please contact the battery supplier.
BE 026
Battery precharge failure
Please contact the battery supplier.
Battery air switch failure
Check that the battery breaker is off.
Please contact the battery supplier.
101
Troubleshooting Troubleshooting
Safety checks should be conducted at least every 12 months, please
contact the manufacturer to arrange for appropriate training,
expertise, and practical experience in performing these tests.
(Please note that this action is not covered by warranty).
These data should be recorded in the device log. If the equipment
is not running properly or any test fails, the equipment must be
repaired for details of safety inspections, refer to section 2 of this
manual for safety instructions and europe commission instructions.
Safety inspections
In the process of using frequency converter, the manager should
check and maintain the machine regularly. The specific operation
is as follows.
1.Check whether the heat sink is covered with dirt, clean the inverter
and absorb dust if necessary. This work should be performed from
time to time.
2.Check whether the frequency converter indicator is normal,
check whether the frequency converter button is normal,check
whether the frequency converter display is normal.
This inspection should be conducted at least every 6 months.
3.Check the input and output lines for damage or aging. This
inspection should be conducted at least every 6 months.
4.Cleaning and safety inspection of PV modules shouldbe
carriedoutatleastonceevery6months.