3.3 Battery(apply to version D/M)
3.5 EPS(Off-grid) Output(apply to version D/M)
3.4 Efficiency, Safety and Protection(apply to version D/M)
3.6 Generic Data(apply to version D/M)
Technical Data
Technical Data
20
21
Battery type
Battery voltage range [d.c. V]
Lithium batteries
180-800
X3-Hybrid-5.0-M
X3-Hybrid-6.0-M
X3-Hybrid-8.0-M X3-Hybrid-10.0-M
X3-Hybrid-12.0-M X3-Hybrid-15.0-M
X3-Hybrid-5.0
X3-Hybrid-6.0 X3-Hybrid-8.0
X3-Hybrid-10.0
X3-Hybrid-12.0 X3-Hybrid-15.0
Model
X3-Hybrid-15.0-M
Integrated
Integrated
YES
YES
YES
YES
YES
Frequency Shift
YES
YES
YES
MPPT efficiency
European efficiency
Maximum efficiency
Max. battery charge efficiency
(PV to BAT)(@ full load)
Max. battery discharge efficiency
(BAT to AC)(@ full load)
Security & Protection
Safety
Grid Monitoring
DC SPD Protection
AC SPD Protection
Over/under voltage protection
Grid protection
DC injection monitoring
Back feed current monitoring
Residual current detection
Active anti-islanding method
Over load protection
Over heat protection
Array insulation resistance detection
99.9%
97.7%
98.2%
98.5%
99.9%
97.7%
98.2%
98.5%
99.9%
97.7%
98.2%
98.5%
97.5% 97.5% 97.5%
99.9%
97.7%
98.2%
98.5%
97.5%
99.9%
97.7%
98.2%
98.5%
97.5%
99.9%
97.7%
98.2%
98.5%
97.5%
X3-Hybrid-5.0-M
X3-Hybrid-6.0-M
X3-Hybrid-8.0-M X3-Hybrid-10.0-M
X3-Hybrid-12.0-M
X3-Hybrid-5.0
X3-Hybrid-6.0 X3-Hybrid-8.0
X3-Hybrid-10.0
X3-Hybrid-12.0 X3-Hybrid-15.0
Model
EPS(Off-grid) rated power[VA]
EPS(Off-grid) rated voltage [a.c. V]
Frequency[ Hz]
EPS(Off-grid) rated current [a.c. A]
EPS(Off-grid) Peak Power [VA]
Switching time [s]
Total harmonic distortion (THDv)
5000
7.2
8000
11.6
10000
14.5
12000, 60S7500, 60s
12000
17.5
15000
21.8
16500, 60S
15000, 60S
9000, 60S 15000, 60S
6000
8.7
400V/230VAC
50/60
<10ms
<3 %
X3-Hybrid-5.0-M
X3-Hybrid-6.0-M
X3-Hybrid-8.0-M X3-Hybrid-10.0-M
X3-Hybrid-12.0-M X3-Hybrid-15.0-M
X3-Hybrid-5.0
X3-Hybrid-6.0 X3-Hybrid-8.0
X3-Hybrid-10.0
X3-Hybrid-12.0 X3-Hybrid-15.0
Model
X3-Hybrid-15.0-M
Dimensions (W/H/D)[mm]
Dimensions of Packing (W/H/D)[mm]
Net weight [kg]
Gross weight* [kg]
Heat dissipation treatment
Noise emission(typical) [dB]
Storage temperature range [ ]°C
Operating Ambient Temperature Range [ ]°C
Humidity [%]
Altitude [m]
Ingress Protection
Protective Class
Cold standby consumption
Overvoltage Category
Pollution Degree
Installation mode
Inverter Topology
Communication interface
Natural Cooling
<40
-40~+70
-35~+60 (derating at 45)
0%~100%
<3000
IP65
I
<5W
III(MAINS), II(PV, Battery)
III
Wall mounted
Non-isolated
Meter/ CT, external control RS485, Pocket series, DRM, USB
Smart Cooling
<45
30 30 30
503*503*199
560*625*322
34 34 34
30
34
30
34
30
34
X3-Hybrid-5.0-M
X3-Hybrid-6.0-M
X3-Hybrid-8.0-M X3-Hybrid-10.0-M
X3-Hybrid-12.0-M
X3-Hybrid-5.0
X3-Hybrid-6.0 X3-Hybrid-8.0
X3-Hybrid-10.0
X3-Hybrid-12.0 X3-Hybrid-15.0
Model
* The specific gross weight is subject to the actual situation of the whole machine.
X3-Hybrid-10.0K-D
X3-Hybrid-10.0K-D
X3-Hybrid-10.0K-D
X3-Hybrid-10.0K-D
IEC62109-1/-2
EN50549, VDE-AR-N 4105, CEI 0-16, CEI 0-21, NRS 097-2-1, AS/NZS 4777.2
Max. continuous charge
/discharge current [d.c. A]
30A
CAN/RS485
Yes
Communication interface
Reverse connection protection