Before connecting the battery, a non-polar DC MCB must be installed to
ensure safety.
Before maintenance, the inverter need to be safely disconnected.
Ø Battery Breaker
Ø Battery connection diagram
Ø Battery connection steps
Ø Connection requirements
Electrical Connection
Electrical Connection
5.4 Battery Connection
Voltage
Current[A]
32A
Model
X3-Hybrid-5.0 X3-Hybrid-6.0 X3-Hybrid-8.0
X3-Hybrid-10.0
Nominal voltage of DC breaker should be larger than maximum
voltage of battery.
X3-Hybrid-12.0 X3-Hybrid-15.0
46
47
Note: The above situation applies to the D/M version.
Step 1. Turn off the DC switch, connect the BAT module, prepare a 6 mm²
BAT cable, and find the BAT (+) terminal and BAT (-) terminal in the package.
Step 3. Tighten the cable with the insulation layer stripped and insert it into
the battery pin contacts (see Figure 1), make sure all wires are well
connected (see Figure 2).
Step 2. Use a wire stripper to strip the 7mm insulation layer of the wire end.
7.0m
m
Wire stripper
Figure 1
Figure 2
Positive battery
pin contact
Negative battery
pin contact
BAT cable
Battery pin contacts
Positive battery connector
Negative battery connector
Positive battery
pin contact
Negative battery
pin contact
High voltage lithium battery
- +
CAN/RS485
Non-polar
DC MCB
Power line connection
Communication line connection
... ...
EPS
com
Upgrade/Dongle
X3-Hybrid-10.0K-D
Positive battery
pin contact
Negative battery
pin contact
Battery port connection line of the M series inverter is on the X3-
Matebox, for specific installation details, please refer to the X3-
Matebox Quick Installation Guide It is necessary to wire the D series
according to the following steps.
Note:
When using our battery, it is recommended to use the number of
battery control ( T-BAT-5.8) is 1, the number of battery modules
(HV11550) is 1-3; the number of battery control (Mc0600) is 1, the
number of battery modules (HV10230) is 2-4.
The inverter charge and discharge system can be equipped with
high voltage lithium battery .
Please note that the maximum voltage of the battery should not
exceed 650 V, battery communication should be compatible with
the inverter.

Other manuals for SolaX Power X3-Hybrid Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power X3-Hybrid Series and is the answer not in the manual?

SolaX Power X3-Hybrid Series Specifications

General IconGeneral
Number of MPP Trackers2
ModelX3-Hybrid Series
PhaseThree Phase
Communication InterfacesRS485
Battery CompatibilityLithium-Ion
Grid Frequency50Hz / 60Hz
Operating Temperature-25 ~ +60 °C

Related product manuals