Setting
Setting
114
115
Setting failed!
Advance Password
Set OK!
Advance Password
Pgrid Bias
>Pgrid Bias
Disable/Grid/INV
23 ) Extend BAT FUNC
24 ) HotStandby Setting
Extend BAT FUNC
Function Control
Enable Disable
HotStandby Seting
Function Control
Enable Disable
26 ) PV Connetion
PV Connection
PV Mode:
MULTI/COMM
Battery charge EVC
Function Control
Enable Disable
22 ) Battery Heating
If the user needs the battery heating function, you can set it to turn on
here, and set the time period that needs to be heated, and the two time
periods can be set. (Only for batteries with heating function)
>Func Select:
Enable Disable
Battery Heating
>Heating Period 1:
Start Time
00:00
Battery Heating
>Heating Period 2:
Start Time
00:00
Battery Heating
>Heating Period 1:
End Time
00:00
Battery Heating
>Heating Period 2:
End Time
00:00
Battery Heating
>Reset
Yes No
Reset Error Log
>Reset Meter/CT1
Yes No
Reset Meter/CT
Reset Error Log
Reset Meter/CT
Reset INV Energy
Reset Wifi
Factory Reset
Reset
>Reset
Yes No
>Reset Meter/CT
Yes No
Reset Meter/CT
Reset INV Energy
>Reset
Yes No
>Reset
Yes No
Reset “Wifi”
Factory Reset
21 ) Reset
Users can reset the reset error log, meter power ,inverter power, and
restore factory settings here.
28 )Advance password
Here you can reset the advanced password. "Set OK!" is displayed on
success, and “Setup Failed!” Will also displayed on failure.
It is “Enable” by default. Setting “Disable” will make the inverter annot
enter standby status.
This function is for extending new batteries. This setting shall be
invalid under the EPS mode. When it is on-grid, enabling this setting
shall make the inverter charge or discharge the battery SOC to about
40%, which is convenient for adding new batteries.
27 ) Battery charge EVC
Here you can set “Enable” to allow the battery to discharge energy to
EV Charger. When you set “Enable”, battery discharging energy to EV
Charger is not allowed.
25) Pgrid Bias
Here you can set whether to discharge more to the grid or prefer to
take power from the grid. If disable is selected , means no preference.
If Grid is selected, the inverter will be biased to discharge the mains; if
INV is selected, the inverter will be biased to take power from the
mains.
This setting depends on the actual connection ways of PV panels.