Troubleshooting Chart – Channel bays
Are the ribbon connectors in the rear of
the Meter Panels seated correctly?
If no, re-seat as required.
Swap Meter Panels 1 and 3. Do the
meters in Bays 2 and 3 now work?
If yes, replace the Meter
Note: Channel Meter information from the
CPU is buffered through Bay 3's Meter to
Bay 2 and then on to Bay 1.
Remove the Meter Panel in Bay 3.
Remove the screening can fitted around
the processor. Check the ribbon
connection in socket PL6.
If no, re-seat as required.
Solo and Cuts Panel in one
Is the ribbon connector on the rear of the
If no, re-seat as required.
Check fuse FS1_4V on the 626630X1
supplied with the console.
Swap the problem panel with a working
panel from another bay. Does the problem
If not, replace the Solo and
Are the ribbon connections to the fader
bus card in the bay displaying the fault
Swap the fader bus card in the faulty bay
with a known working bus card from an
alternate bay. Does the problem stay in
If no, replace the fader bus
Raising the Channel Fader
Swap the fader with one from an adjacent
channel. Does the problem follow the
If yes, replace the fader.
Swap the channel strip with an adjacent
channel. Does the problem follow the
If yes replace the channel
All channel strips in one
Refering to Control Overview diagram,
ensure that the Multidrop Bus connector
between the Channel Backplane and the