3-10
BRC-300/300P
BRU-300/300P
3-2. BRC-300/300P Camera Block Electrical Alignment
3-2-7. Data Initialization of Pages 8, A, C, D,
E, F, 1E, 1F
After replacing the IF-110 board, VISCA CPU (IC403/IF-
110 board), or VC-343 board, initialize the page data.
Initialization Procedure
1. Date initialization of pages A and D
2. Date initialization of pages 8 and C
3. Date initialization of pages E, F, 1E, and 1F
1. Date initialization of pages A and D
n
If “Date initialization of pages A and D” is performed, all
data of the page A and page D will be initialized. (It is
impossible to initialize a single page.)
Adjusting page Adjusting address
A 00 to FF
D 00 to 7F
Initializing method
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 0 10 00 Set the data.
3 2 00 Set the following data.
55 (NTSC)
51 (PAL)
4 2 01 Set the data, and press
PAUSE button.
55 (NTSC)
51 (PAL)
5 2 02 Check that the data changes to
“01”.
6 2 00 29 Set the data.
7 2 01 29 Set the data, and press
PAUSE button.
2. Date initialization of pages 8 and C
m
. If “Date initialization of pages 8 and C” is performed, all
data of the page 8 and page C will be initialized. (It is
impossible to initialize a single page.)
. After initializing the data of pages 8 and C, perform the
adjustments in Sections 3-2-8 and 3-2-9 again.
Adjusting page Adjusting address
8 00 to A3
C 10 to FF
Initializing method
Order Page Address Data Procedure
1 0 01 01 Set the data.
2 0 10 00 Set the data.
3 3 81 Check that the data is “00”.
4 3 80 0C Set the data, and press
PAUSE button.
5 3 80 Check that the data changes to
“1C”.