155
Event Operations
Chapter 6 Registering Operations and Settings
Deleting Events
Use the following procedure to delete registered events.
1
Press the EVENT button in the numeric keypad.
The numeric keypad enters event mode.
The most recently used sub menu appears in the
display panel.
2
If the INSERT button is lit, press it to turn it off.
The Event Data sub menu appears.
3
Rotate the F1 knob to select a page.
4
Press the STORE button.
5
With the SHIFT button in the DME/SETUP block
(when using the BKDF-901) or the KEY SRC button
in the key/AUX bus control block (when using the
BKDF-902) held down, press the event registration
button to which the event that you want to delete has
been assigned.
The button changes from lit in green to not lit, and the
event registered for that button is deleted.
To delete events in page units
You can delete multiple registered events at once by
deleting them in page units.
In event mode, select a page, and then press the F4 (Initial)
knob and hold it down for one second or longer.
To recall events from an editor
Setting the communications protocol to GVG100 (see
page 162) allows specifying an E-FILE (event file)
number to recall individual events from the BVE-2000.
The following figure shows the correspondence between
the events on each page and E-FILE numbers, using the
arrangement of buttons on the numeric keypad.
Events numbers 50 to 98 can be specified from the BVE-
2000. (The BVE-2000 can operate numbers up to 99, but
number 99 is reserved for “Init Panel”.)
On how to use the BVE-2000, refer to the User’s Guide
supplied with the BVE-2000.
BKDF-901
BKDF-902
Numeric
keypad
789
456
123
0NewDel
Event
Page P1 P2 P3 P4 P5
E-FILE
50 51 52 62 63 64 74 75 76 86 87 88 98
53 54 55 65 66 67 77 78 79 89 90 91
56 57 58 68 69 70 80 81 82 92 93 94
59 60 61 71 72 73 83 84 85 95 96 97