6-24
DSC-F828
14. CCD Linearity Check
Data picking is done to keep output linearity of the CCD imager,
even if the input level of CCD imager changes.
Mode STILL(P AUTO) (P)
Subject Clear chart (PTB-1450/PTB-450)
(Standard picture frame)
Measurement Point
Data of page: 10, address: 80, 81, 82, 83
Measuring Instrument
Specified value1 97 to 103 (Note1)
Specified value2 94 to 106 (Note1)
Specified value3 92 to 108 (Note1)
Specified value4 97 to 104 (Note1)
Specified value5 94 to 109 (Note1)
Specified value6 92 to 112 (Note1)
Note1: Decimal number.
Note2: If the data of page: 60, address: 02 is 01, select page: 60, address:
01, and set data: 00.
Note3: For the bit values, refer to 6-2. SERVICE MODE, 2-2. 2. Bit
value discrimination.
Switch setting:
ZOOM ....................................................................WIDE end
Preparation:
Order Page
Address
Data Procedure
1 Install the clear chart.
2 Check that 1. Data Setting
during Camera System
Adjustments is performed.
3 Check the picture frame. If
deviated, perform 5. or 6.
Picture Frame Setting.
4 75 09 Read the data, and memorize it.
5 75 09 04 Set the data.
6 77 F6 Read the data, and memorize it.
7 77 F6 Set Bit2 of the data to 0. (Note3)
8 77 F7 Read the data, and memorize it.
9 77 F7 Set Bit6 of the data to 1. (Note3)
10 77 F2 Read the data, and memorize it.
11 77 F2 Set Bit6 of the data to 0. (Note3)
12 77 F2 Set Bit0 of the data to 0. (Note3)
13 77 72 Read the data, and memorize it.
14 60 14 90 Set the data.
15 60 12 9F Set the data.
16 75 17 Read the data, and memorize it.
17 75 17 AA Set the data.
18 75 18 Read the data, and memorize it.
19 75 18 00 Set the data.
20 75 19 Read the data, and memorize it.
21 75 19 E8 Set the data.
22 75 1A Read the data, and memorize it.
23 75 1A 54 Set the data.
24 75 1B Read the data, and memorize it.
25 75 1B 74 Set the data.
26 Wait for 2 sec.
Checking method:
Order Page
Address
Data Procedure
1 Perform Preparation before
this adjustment.
2 60 01 F9 Set the data.
3 Wait for 2 sec.
460E1
Read the data, and check it is 08.
5 10 80 Read the data, and this data is
named D80.
6 10 81 Read the data, and this data is
named D81.
7 Calculate DRG0 using the
following equation
(Hexadecimal calculation)
DRG0 = D80 × 100 + D81
8 10 82 Read the data, and this data is
named D82.
9 10 83 Read the data, and this data is
named D83.
10 Calculate DBG0 using the
following equation
(Hexadecimal calculation)
DBG0 = D82 × 100 + D83
11 60 01 00 Set the data.
12 60 E1 00 Set the data.
13 77 72 48 Set the data.
14 Wait for 2 sec.
15 60 01 F9 Set the data.
16 Wait for 2 sec.
17 60 E1
Read the data, and check it is 08.
18 10 80 Read the data, and this data is
named D80.
19 10 81 Read the data, and this data is
named D81.
20 Calculate DRG1 using the
following equation
(Hexadecimal calculation)
DRG1 = D80 × 100 + D81
21 10 82 Read the data, and this data is
named D82.
22 10 83 Read the data, and this data is
named D83.
23 Calculate DBG1 using the
following equation
(Hexadecimal calculation)
DBG1 = D82 × 100 + D83
24 60 01 00 Set the data.
25 60 E1 00 Set the data.
26 77 72 0C Set the data.
27 Wait for 2 sec.
28 60 01 F9 Set the data.
29 Wait for 2 sec.
30 60 E1
Read the data, and check it is 08.
31 10 80 Read the data, and this data is
named D80.
32 10 81 Read the data, and this data is
named D81.