6-42
DSC-F828
10. Record of Use check
Page 4F Address 94 to 97
Using method:
1) The recording counter data is displayed at page: 4F, addresses: 94 to 97. These data are named D94, D95, D96 and D97 respectively.
2) Calculate the recording counter (N) using following equation. (Hexadecimal calculation)
N = D97 + D96 × 100 + D95 × 10000 + D94 × 1000000
Address
94
95
96
97
Function
Recording counter
(Hexadecimal)
Remarks
1000000-digit and 1000000-digit
1000000-digit and 10000-digit
1000-digit and 100-digit
10-digit and 1-digit
11. Self Diagnostics Log check
Page 20 Address B0 to B8
*1: “C” t “01”, “E” t “03”
Using method:
1) The self diagnostics log is displayed at page: 20, addresses: B0 to B5.
Note: These data will be erased when the lithium battery (LR-018 board) is removed.
Address
B0
B1
B2
B3
B4
B5
B6
B7
B8
Initial value
00
00
00
00
00
00
00
00
00
Function
“Repaired by” code (Occurred 1st time) *1
“Block function” code (Occurred 1st time)
“Detailed” code (Occurred 1st time)
“Repaired by” code (Occurred 2nd time) *1
“Block function” code (Occurred 2nd time)
“Detailed” code (Occurred 2nd time)
“Repaired by” code (Occurred 3rd time) *1
“Block function” code (Occurred 3rd time)
“Detailed” code (Occurred 3rd time)