4-11
DSR-2000A/2000AP
22
22
2 Main code 21
Sub Detected contents Operation after Operable mode Display period
code detecting an
abnormality
0C8 Detected the abnormal current in the reel position motor. AUTO OFF EJECT Displayed until the
(Emergency EJECT) next cassette is
OE8 Detected the abnormal current of M stop plunger solenoid.
inserted.
1C1 Failed to complete the reel position movement within the Cassette tape
specified time. will be ejected.
33
33
3 Main code 22
Sub Detected contents Operation after Operable mode Display period
code detecting an
abnormality
0D8 Detected an abnormal current of cleaning plunger solenoid. AUTO OFF EJECT Displayed until the
(Emergency EJECT) next cassette is
inserted.
..
..
. Main code 3X : Sensor trouble
Sub codes are all 000.
Sub Detected contents Operation after Operable mode Display period
code detecting an
abnormality
31 Failed to release the tape top. STOP PLAY, FF, EJECT Displayed until the
32 Failed to release the tape end. STOP PLAY, REW, EJECT
error is solved and
33 Detected an abnormal current of reel shift sensor LED. Insertion of _
any key is
cassette tape is
pressed.
inhibited.
34 Detected an abnormality of threading sensor. Cassette tape insertion and unthreading
35 Detected an abnormality of cassette compartment position
are prohibited until the error is solved.
sensor.
36 Detected an abnormality of fan motor. Only error is _
displayed.
39 Detected an abnormality of cassette top/end sensor LED. STOP PLAY, EJECT
3A Detected an abnormality of tension sensor. AUTO OFF EJECT