10-5 (N)
DSR-80/80P/60/60P
10-5-1. Recorder/Player Adjustment
10-5-1-1. INT SC Frequency Adjustment
(Connection)
10-5-1-2. HCK Adjustment
Conditions for adjustment Adjustment
..
..
. Specification
. STOP mode
. REF. VIDEO IN ; No signal
TP601/IO-149 (B-2)
1CT602/IO-149 (A-3)
Frequency counter
Spec. f=3,579,545 ±10 Hz
Conditions for adjustment Adjustment
..
..
. Specification
. STOP mode
Connection 1
TP602/IO-149 (A-4)
1CT601/IO-149 (A-3)
Oscilloscope
Spec. A=2.50 ±0.05 Vdc