EasyManua.ls Logo

Sony ICP-X1224 - Synchronizing the Network

Sony ICP-X1224
532 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
449
Synchronizing the
Network
You can set the network synchronization function
required for ST 2110 transmission. This function uses the
PTP protocol.
1
Open the Home > Setup > 100G IP I/F > Genlock
menu (19108.31).
2
In the [Primary LAN] group, press the [Genlock]
button to enable/disable the network synchronization
function.
On: E
nable network synchronization on the primary
LAN.
Off:
Disable network synchronization on the primary
LAN.
3
In the [Primary LAN] group, press the [Domain]
button and enter the domain number of the PTP leader
using the numeric keypad.
4
In the [Primary LAN] group, select the
communication method of the PTP leader from the
[Communication Mode] pull-down list.
Multicast:
Multicast response to multicast signal
from the leader
Mixed: U
nicast response to multicast signal from the
leader
5
In the [Secondary LAN] group, press the [Genlock]
button to enable/disable the PTP function.
On:
Enable network synchronization on the
secondary media LAN.
Off: Disa
ble network synchronization on the
secondary media LAN.
6
In the [Secondary LAN] group, select the
communication method of the PTP leader from the
[Communication Mode] pull-down list.
Multicast:
Multicast response to multicast signal
from the leader
Mixed: U
nicast response to multicast signal from the
leader
7
Press the [Apply] button.
To return to the previous setting
Press the [Clear] button.
8
Check the message, then press [OK].
To check the network synchronization state
The following network synchronization information is
di
splayed for each box under [Genlock Status] in the
Home > Setup > 100G IP I/F > Genlock menu
(19108.31).
Logical box ID number (1 to 5)
Primary LAN status information
Secondary LAN status information
The following status information is displayed.
--: Network synchronization function disabled
No Master: PTP leader cannot be found
Locking: Synchronizing with PTP leader
Locked: Synchronized with PTP leader