Connections 29 (GB)
Connections
INPUT B: Setting the QB board
Sync 75-ohm terminate connector: Normally set to “1K”. Set the CN10
and CN11 to “75” when the sync output signal is terminated at 75 ohms.
Sync separate connector: Set the CN12 to change the sync on green
signal to the separate sync signal. Set it to “HS SEP” when the HDTV
external sync signal, etc. is input.
Pin positions set at the factory
How to switch the connector
3
2
1
CN10 CN11
123
CN12
H/C TERM
3
2
1
1k
75
123123
1k
75
V TERM
HS NORM
HS FIX
HS SEP